• ANWETECH AT-S220 Standalone Photoelectric Smoke Alarm | EN14604 Battery Smoke Detector
  • ANWETECH AT-S220 Standalone Photoelectric Smoke Alarm | EN14604 Battery Smoke Detector

ANWETECH AT-S220 Standalone Photoelectric Smoke Alarm | EN14604 Battery Smoke Detector

No.AT-S220

ANWETECH AT-S220 is a standalone photoelectric smoke alarm designed for household and similar residential applications. Powered by a 9V battery, it provides early warning of smoke at the initial stage of fire with a red LED, built-in buzzer and hush function for temporary alarm silence.

  • ANWETECH AT-S220 Standalone Photoelectric Smoke Alarm | EN14604 Battery Smoke Detector

Description

Product Description

The ANWETECH AT-S220 is a standalone photoelectric smoke alarm designed to provide early warning of fire in homes and similar residential spaces. Using photoelectric smoke sensing technology, it responds effectively to smoldering fires and helps give occupants more time to control the fire or evacuate safely.

The detector is powered by a 9V battery and does not require connection to a fire alarm panel, making it simple to install and suitable for residential retrofit projects. During normal standby, the red LED flashes periodically. When smoke is detected, the detector activates an audible alarm and visual indication. A hush function is also included to temporarily suppress nuisance alarms when necessary.

With compact size, low standby current and EN14604 compliance, AT-S220 is suitable for apartments, houses, bedrooms, corridors and other household applications where reliable standalone smoke detection is required.


Key Features

  • Standalone photoelectric smoke alarm
  • Designed for household and similar residential applications
  • Battery powered, easy to install
  • Complies with EN14604:2005/AC:2008
  • Red LED and buzzer alarm indication
  • Hush function for temporary alarm silence
  • Low standby current
  • Compact ceiling-mounted design
  • Suitable for bedrooms, living rooms, corridors and residential projects

Technical Specifications

Model No.: AT-S220
Standard: EN14604:2005/AC:2008
Voltage: DC 9V
Standby current: ≤10 μA
Alarm current: ≤30 mA
Sensor type: Photoelectric
Temperature: 0°C to +40°C
Ambient humidity: ≤95% RH
Hush time: 8 to 9 min
Alarm indication: Red LED & buzzer
Sound pressure: ≥85 dB (around 3 m)
Net weight: 88 g (battery not included)
Product size: Ø100 × 37 mm
Installation way: Ceiling mounting


Recommended Installation Location

  • Install at the highest point of the ceiling, as smoke rises upward
  • Keep at least 0.5 m clearance around the detector
  • Do not install too close to gas cookers or heat sources
  • Do not install in kitchens where cooking fumes may cause false alarms
  • Do not install in bathrooms or high-humidity areas
  • In large rooms, keep the distance between two detectors within 10 m
  • Avoid dusty areas and garages where nuisance alarms may occur

Applications

  • Houses and apartments
  • Bedrooms and living rooms
  • Corridors and stair areas
  • Residential retrofit projects
  • Villas and small residential buildings

Download