The ANWETECH AT-EH03 Rod Type Temperature Detector is a fixed-temperature fire detection device designed for industrial and special hazard environments.
It can be installed in protected areas as a temperature alarm device. When the surrounding temperature reaches the preset alarm value, the detector sends an alarm signal. Unlike conventional rate-of-rise heat detectors, it is not affected by short-term temperature fluctuation or the speed of temperature increase.
The detector can be used as a normally open temperature switch in fire alarm systems. It is suitable for explosion-proof applications and provides IP67 protection for harsh industrial environments.
Product Model: AT-EH03 Series
Product Type: Rod Type Fixed Temperature Detector
Detection Principle: Fixed temperature activation
Environmental Temperature: -40°C to 180°C
Explosion-Proof Grade: Flameproof type, Ex d IIC T6
Protection Grade: IP67
Total Length: 107 mm
Diameter: 14.1 mm
Assembly Thread: NPT 1/2"
Thread Length: 25 mm
Contact Output: Normally open temperature switch contact
| Voltage | Current |
|---|---|
| 6–125 VAC | 5 A |
| 6–25 VDC | 1 A |
| 125 VDC | 0.5 A |
| ANWETECH Model | Alarm Temperature | Description |
|---|---|---|
| AT-EH03-60 | 60°C / 135°F | Explosion-proof rod type fixed temperature detector |
| AT-EH03-85 | 85°C / 185°F | Explosion-proof rod type fixed temperature detector |
| AT-EH03-90 | 90°C / 194°F | Explosion-proof rod type fixed temperature detector |
| AT-EH03-105 | 105°C / 221°F | Explosion-proof rod type fixed temperature detector |
| AT-EH03-125 | 125°C / 257°F | Explosion-proof rod type fixed temperature detector |
| AT-EH03-140 | 140°C / 284°F | Explosion-proof rod type fixed temperature detector |
| AT-EH03-162 | 162°C / 325°F | Explosion-proof rod type fixed temperature detector |
| AT-EH03-232 | 232°C / 450°F | Explosion-proof rod type fixed temperature detector |
The ANWETECH AT-EH03 Rod Type Temperature Detector is suitable for areas where fixed-temperature fire detection is required, especially in harsh or industrial environments.
Application areas include:
Steel mills
Switchgear rooms
Transformer rooms
Substations
Motor control centers
Resistor banks
Power distribution equipment
Power cable joints and turns
Cable trays
Cable tunnels
Cable mezzanines
Cable trenches
Cable shafts
Belt conveyors
Automated assembly lines
Automobile painting and coating workshops
Machinery manufacturing workshops
Aluminum and copper rolling mills
Cold storage warehouses
High-density warehouses
Wine warehouses
General storage warehouses
Hydraulic stations
Lubricating oil depots
Oil pipe galleries
Oil product transfer areas
Cooling towers
Dust collectors
Multi-storey elevated parking garages
The detector is normally installed near the protected object or high-risk temperature point. When the temperature around the sensing rod reaches the preset value, the internal contact changes status and sends a fire alarm signal to the connected fire alarm control system or monitoring device.
For hazardous area applications, external wiring should be designed according to the project’s explosion-proof requirements. Where intrinsically safe circuits are required, suitable safety barriers should be used.